Forum Post: Resetting ISUP circuit groups fails and S7MGT: FAILED
Hi, I am trying to configure 2 ISUP circut groups each gorup as 24 voice CIC's 1st T1 : all 24 channels for vocie 2nd T1: all 24 channels for voice Below is the configuration: * Configure ISUP...
View ArticleForum Post: RE: Using mm_Capture() to take an image from a video call
Hi Brendan, Could you please check if the transcoding is ON between the devices? Thanks, Sunil.
View ArticleForum Post: working of dsistat
Hi Experts; please any one describe "How dsistat works?" i have a command "./dsistat CCTS STATUS 0" which is use for know the status of all channels of 1st e1. i want to know that how i know the...
View ArticleForum Post: RE: Resetting ISUP circuit groups fails and S7MGT: FAILED
S7_MGT Tx: M-I0000-t7303-i0000-fcf-d22-s00-r8000-p000622ef00000001000000000008000800ef00000000000400000033002300000000000000000000 S7_MGT Rx:...
View ArticleForum Post: Not Re regestering On Grandstream Ucm6102
HMP is not re registering after an hour Voip Call comes in to Grandstrim UCM6102 and then transferred to VoiceGide that uses the Dialogic HMP VG and UCM are on the same LAN VG=192.168.0.120 and...
View ArticleForum Post: Regarding Certificate Issue for WebRTC
I am using XMS 3.2 and started to run the WebRTC demo application but I am getting error like "Failed to Get Access to Local Media" and when I check the logs I am seeing the below error . SHA-1...
View ArticleForum Post: Changing Contact Header in 200 OK response HMP
Hi, I have one question . When i receive incoming INVITE request uri is in format tel:number so HMP automaticly puts this in Contact header in 200 OK response . Is it possible to change this...
View ArticleForum Post: RE: ERROR - unexpected message
Hi Jeff, I'm facing the same with HMP 4.1.213 [root@mgw1-test jinny]# cat /usr/dialogic/cfg/buildinfo Dialogic(R) HMP Software Release LIN System Release Build Date = 12/18/2015 System Release Build...
View ArticleForum Post: RE: Changing Contact Header in 200 OK response HMP
Refer to Section 4.9 Setting and Retrieving SIP header messages fields from the Global IP Tech Guide here: www.dialogic.com/.../globalcall_for_ip_hmp_v12.pdf Jeff
View ArticleForum Post: HMP is not Re regestring after an hour
HMP is not re registering after an hour the SIP device and phone stops working This is my setup : Voip Call comes in to Grandstrim UCM6102 and then transferred to VoiceGuide that uses the Dialogic...
View ArticleForum Post: Dialogic IMG 2020 offline configurator
Hi, Where can I find link to download Offline configurator for IMG 2020 ? DOes anyone know? https://www.dialogic.com/webhelp/IMG2020/2.3.0/WebHelp/default.htm#offline_configurator.htm FR19070 Offline...
View ArticleForum Post: RE: ERROR - unexpected message
Hi, As stated prior I had seen this type of error show up when host library sends commands down to firmware in an unexpected state. You would have to check the RTF log for any error, or what APIs may...
View ArticleForum Post: RE: ERROR - unexpected message
Hi Jeff, Can you please help us identifying the root cause? I've uploaded the RTF log to the below location: https://www.dropbox.com/s/lffolv7t5s8nyp0/rtflog-LOCAL-20170110-12h36m19.677s.txt?dl=0...
View ArticleForum Post: RE: ERROR - unexpected message
Just to clarify is your app running in 3PCC mode? I see some events in log which indicate that. Also, it seems there is a fair amount of INVITE being rejected with 603 Declined in this case. That...
View ArticleForum Post: RE: ERROR - unexpected message
Hi Jeff, Our application is running in 3PCC mode. The Status Code 603 is normal because it is generated by one of our application which is missed call alert. The amount of ERROR is very small...
View ArticleForum Post: RE: D/480 JCT - 2T1. Genload.exe: Power Requirement was not met...
I am getting the same error, even after setting the jumper to 2-3. I am using a Lenovo System-x 3650 server with Windows 2012 R2.
View ArticleForum Post: fx_rcvfax, stored RAW fax data encoding
Hello, Is there a way to determine format of the RAW data that Dialogic stores in the file after issuing fx_rcvfax function in HMP? First, I thought that this format depends only on hardware...
View ArticleForum Post: RE: D/480 JCT - 2T1. Genload.exe: Power Requirement was not met...
Hi, To be more specific since different products and errors were seen in the prior trail of this discussion. What exact board are used in this case? Are they detected correctly in the windows device...
View ArticleForum Post: RE: ERROR - unexpected message
From a quick check I see this showed up during a gc_dropcall (or around that time) and suspect that it has to due with handling of RTP steam via IPML. From other cases we had seen in the past, this...
View Article