Forum Post: DSI SS7G41 Signaling Server SIU Mode Software updated to Release...
The SS7G41 Signaling Server SIU Mode Software Release 2.4.9 is now released to GA status and is available for download from the DSI Signalling download pages .
View ArticleForum Post: DSI Development Package for Linux updated to Release 6.8.18
The DSI Development Package for Linux has been updated to Release 6.8.18 and is now available for download.
View ArticleForum Post: DSI Development Package for Windows updated to Release 6.5.0
The DSI Development Package for Windows has been updated to Release 6.5.0 and is now available for download.
View ArticleForum Post: NET5 protocol on DMV1200 problem
I have two E1 links , one from PSTN and one from Ericson PBX. I used CTR4 protocol for both links and D/600 board worked fine. Now I changed my board to DMV1200 (DM3 board) and changed protocol to...
View ArticleForum Post: RE: SIP: How to change or remove QoS attributes in the SDP OK status
Hi Mekhman, As of right now the code changes I am referencing have not been released as of yet in HMP 3.0 SU. However, I only suspect that could potentially help but can't say for sure if that is the...
View ArticleForum Post: RE: gc_basic_call_model - how can I generate an outgoing call?
Hi Mike, As I alluded to before the gcbcm application is designed to read the provided config file in order to determine the direction (I.e. IN or OUT) of which a specified channel will run in this...
View ArticleForum Post: RE: gc_hmp_hold_retrieve demo project - the call is successful...
Hi Mike, I just downloaded the source from the Technote of which covers this topic: www.dialogic.com/.../pm_hmp_win And it recompiling to update the project to something newer, it worked as is from...
View ArticleForum Post: RE: gc_hmp_hold_retrieve demo project - the call is successful...
Hi Jeff, Thank you for your answer. 1. I am trying to compile the project using Visual Studio version 2017. I am getting an error: Error D8016 '/ZI' and '/Gy-' command-line options are incompatible...
View ArticleForum Post: RE: gc_hmp_hold_retrieve demo project - the call is successful...
Hi Jeff, In addition there is an error in the code in the gc_demo_open_vox_channel(int index) function: if (port[index].direction == DIR_IN) { sprintf(port[index].play_filename,"prompt.pcm",index); }...
View ArticleForum Post: RE: gc_hmp_hold_retrieve demo project - the call is successful...
Jeff, I was able to compile the project and run it.The phone rings and the call is answered. However, no voice file is heard.... See the log below. ****** GC DEMO - BASIC CALL HOLD...
View ArticleForum Post: DCM error - The system is in start/stop pending mode...
Hi, When I start the DCM program, I get the following error. Any idea why and how to fix? Thanks. Mike
View ArticleForum Post: RE: DCM error - The system is in start/stop pending mode...
sometimes when board is changed , you may see this happens. just end task dialogic service from task manager. then check if dialogic is detected in device manager if you dont see any device in device...
View ArticleForum Post: RE: DCM error - The system is in start/stop pending mode...
Edwin, Thank you for your answer. Please note that I am using HMP, not a physical board. Mike
View ArticleForum Post: Send and Receive Fax on HMP
Hi Is there any fax resource license for HMP? can I send and receive fax with HMP and no physical board ?
View ArticleForum Post: RE: Send and Receive Fax on HMP
In short, yes, there are fax ports that available to be purchased in a HMP based license. Similar to that of virtual voice devices. Jeff
View ArticleForum Post: RE: DCM error - The system is in start/stop pending mode...
Hi, Can you remind me of the specific Windows OS version in use in this case? Also what was the HMP SU version? I don't recall those points from prior conversations. Jeff
View ArticleForum Post: RE: gc_hmp_hold_retrieve demo project - the call is successful...
Going back to my prior question, "Make sure the correct box is checked for the IP address intended to be used for RTP streaming (on the system) from the "default IP address" tab of the HMP device...
View ArticleForum Post: RE: DCM error - The system is in start/stop pending mode...
Hi, Windows 10 Pro 64 bit, Ver 1709. HMP Software Release 3.0 SU 375. Thanks. Mike
View ArticleForum Post: RE: gc_hmp_hold_retrieve demo project - the call is successful...
Jeff, See the screen capture below. Is the IP correct? Thanks. Mike
View Article